Solar Power Plant Automation

Solar facilities may use automation for balance-of-plant and auxiliary functions such as tracker positioning interfaces, cleaning systems, auxiliary pumps, weather measurements and inverter/transformer auxiliary status. PLC/SCADA scope should complement, not replace, the inverter's internal controls, grid protection or certified plant-level power-control functions. Automation scope depends on the equipment, operating sequence, existing controls and process requirements. Share the machine details and desired outcome to define a suitable control approach.

Vendor interface and supervisory architecture

Map each inverter, tracker, weather station and auxiliary package to its supported interface and data ownership. Identify which values are read-only and which commands are permitted, how stale or failed communications are shown, and how the plant SCADA distinguishes local equipment control from auxiliary supervision.

Application overview

Solar facilities may use automation for balance-of-plant and auxiliary functions such as tracker positioning interfaces, cleaning systems, auxiliary pumps, weather measurements and inverter/transformer auxiliary status. PLC/SCADA scope should complement, not replace, the inverter's internal controls, grid protection or certified plant-level power-control functions.

Typical requirements to define

  • Plant layout, equipment schedule and boundary between auxiliary PLC, inverter and plant controller
  • Tracker type and vendor interface where tracking is used, including position and fault status
  • Weather-station instruments and required signals such as irradiance, wind or ambient temperature
  • Auxiliary pump, cleaning-system, motor, valve and power-supply details
  • SCADA tags, alarms, time synchronization, communication gateways and operating responsibilities

Example process sequence

  1. Check auxiliary controller health, mode, available communication and equipment permissives.
  2. Collect weather and equipment-status signals and validate their quality where diagnostics are available.
  3. Issue only approved commands to tracker or cleaning-system interfaces and confirm position/run feedback.
  4. Coordinate auxiliary pumps or other balance-of-plant equipment according to the defined sequence.
  5. Present alarms, status and selected trends to supervisory operators; leave inverter and grid-control responses to designated systems.

Trackers and cleaning auxiliaries

Where used, a PLC may supervise vendor-provided tracker positioning or cleaning equipment interfaces, monitor run/position/fault feedback and enforce agreed permissives. Mechanical limits and tracker control ownership must remain clear.

Weather and balance-of-plant signals

Weather-station data and auxiliary pump or transformer/inverter auxiliary status can be collected when available through compatible instruments or gateways. Data quality and stale-signal alarms should be defined.

Inverter and grid-control boundary

The inverter's internal control, grid protection and any certified plant-level power-control functions are separate system responsibilities. Integration should use vendor-approved interfaces and must not imply their replacement.

Related automation technologies

Explore the control systems that may be relevant to this scope.

Products from the catalog

These active catalog products are related by their existing category. Confirm model compatibility, condition, availability and delivery for your destination before ordering.

Delta VFD1850C43A-00 C2000+ 185kW 250HP VFD

VFD & Drives

Delta VFD1850C43A-00 C2000+ 185kW 250HP VFD

Brand: Delta · Model: C2000

Delta C2000+ VFD1850C43A-00, 185 kW / 250 HP, 460 V three-phase industrial AC drive for advanced motor speed and torque control.

Siemens 6AV2123-2GB03-0AX0 KTP700 Basic HMI – 7" Touchscreen, 800×480, PROFINET

HMI

Siemens 6AV2123-2GB03-0AX0 KTP700 Basic HMI – 7" Touchscreen, 800×480, PROFINET

Brand: Siemens · Model: KTP700

Siemens KTP700 Basic HMI, 6AV2123-2GB03-0AX0, with 7-inch TFT touchscreen, 800×480 resolution, 65,536 colors, PROFINET communication and 24VDC supply.

Baling Machine Automatic Control Panel for 10 HP Motor – Relay & Contactor Based

Control Panel Components

Baling Machine Automatic Control Panel for 10 HP Motor – Relay & Contactor Based

Brand: MECHATRONICS AUTOMATION · Model: MAES-0002

Automatic relay and contactor-based control panel for 10 HP baling machines, providing automatic cycle control, motor protection, limit-switch sequencing, fault indication and operator controls without a PLC.

AGSS Fully Automatic Control Panel – Automatic Gas Scavenging System Control Panel

Control Panel Components

AGSS Fully Automatic Control Panel – Automatic Gas Scavenging System Control Panel

Brand: MECHATRONICS AUTOMATION · Model: MAES-001

Fully automatic AGSS control panel for automatic operation and monitoring of two-stage vacuum/scavenging systems, featuring HMI monitoring, automatic pump control, pump selection, alarms, protection and emergency stop.

Siemens S7-1200 CPU 1214C DC/DC/DC PLC – 14DI/10DO/2AI, 6ES7214-1AG40-0XB0

PLC

Siemens S7-1200 CPU 1214C DC/DC/DC PLC – 14DI/10DO/2AI, 6ES7214-1AG40-0XB0

Brand: SIEMENS · Model: 6ES7214-1AG40-0XB0

Siemens S7-1200 CPU 1214C DC/DC/DC PLC with 14 digital inputs, 10 digital transistor outputs and 2 analog inputs. 24 V DC supply, 150 KB program/data memory and PROFINET communication.

RS232 PLC HMI Communication Cable – DB9 Serial Programming Cable for Industrial Automation

Industrial Communication

RS232 PLC HMI Communication Cable – DB9 Serial Programming Cable for Industrial Automation

Brand: Mechatronics Automation · Model: MAES-COMM-3

RS232 serial communication cable for compatible PLCs and HMIs, suitable for programming, configuration, commissioning, diagnostics and industrial automation communication.

Delta VFD EL SERIES 0.025 TO 5 HP | 0.2KW TO 3.7KW

VFD & Drives

Delta VFD EL SERIES 0.025 TO 5 HP | 0.2KW TO 3.7KW

Brand: DELTA · Model: VFD002EL21A

Delta VFD002EL21A 0.2kW (0.25HP) VFD with 200–240V single-phase input, 3-phase output, 1.6A rated output current, V/F control, RS-485 Modbus, built-in braking transistor and 0.1–600Hz frequency range.

Delta DOP-107CV 7 Inch Touchscreen HMI – 800×480 TFT, RS-232/RS-485/RS-422, USB

HMI

Delta DOP-107CV 7 Inch Touchscreen HMI – 800×480 TFT, RS-232/RS-485/RS-422, USB

Brand: DELTA · Model: DOP107CV

Delta DOP-107CV 7-inch industrial touchscreen HMI with 800×480 resolution, 65,536-color TFT display, 256 MB RAM/ROM, RS-232/RS-485/RS-422 communication, USB Host/Client, and 24 VDC power supply.

Related engineering services

View automation services →

Frequently asked questions

Can solar plant automation include tracker positioning?

A PLC may supervise tracker interfaces where the tracker vendor provides a compatible, approved command and feedback method. Tracker safety and control responsibilities should remain defined by the equipment design.

Can weather-station and inverter auxiliary data be monitored?

Available signals can be integrated through compatible instruments or gateways for display, alarm or trend use. Exact data points and update behavior depend on the supplied equipment.

Does this automation replace inverter or grid protection controls?

No. Inverter internal control, grid protection and certified plant-level power-control functions remain with their designated systems.