Industrial Automation Products · Engineering Services · Quote Support

Utilities

HVAC Automation

HVAC automation coordinates relevant heating, cooling, ventilation and equipment states around the installed system and operating requirements. Automation scope depends on the equipment, operating sequence, existing controls and process requirements. Share the machine details and desired outcome to define a suitable control approach.

Application overview

HVAC automation coordinates relevant heating, cooling, ventilation and equipment states around the installed system and operating requirements.

Typical requirements to define

  • System equipment and control boundaries
  • Temperature and other required sensor locations
  • Operating schedules, modes and setpoints
  • Equipment permissives, alarms and overrides

Example process sequence

  1. Evaluate schedule, demand and system readiness
  2. Enable relevant equipment in the configured order
  3. Monitor process feedback and equipment status
  4. Adjust control outputs within approved operating limits
  5. Report alarms and return equipment to the required state

PLC sequence and machine states

Translate the agreed process into explicit states, transitions, permissives, alarms and recovery behavior. The final sequence should be reviewed against the machine's actual operating procedure.

Machine states and operating sequence

Document the machine cycle, operator actions, required permissives, abnormal conditions and safe recovery path before mapping them to controller logic.

Operator interface and alarms

An HMI may show mode, step, status, setpoints and actionable alarm information. Screen behavior and operator permissions should match the plant's procedures.

Safety and fault handling

Safety functions must be designed for the risk assessment and applicable machine requirements. Standard PLC logic should not be treated as a substitute for safety-rated hardware or a validated safety design.

Temperature and system control

Temperature loops and equipment sequencing depend on sensor placement, system response and the HVAC design. Operating values should be supplied by the responsible project engineer.

Related automation technologies

Explore the control systems that may be relevant to this scope.

Products from the catalog

These active catalog products are related by their existing category. Confirm model compatibility and availability for your application.

Siemens S7-1200 CPU 1214C DC/DC/DC PLC – 14DI/10DO/2AI, 6ES7214-1AG40-0XB0

PLC

Siemens S7-1200 CPU 1214C DC/DC/DC PLC – 14DI/10DO/2AI, 6ES7214-1AG40-0XB0

Siemens S7-1200 CPU 1214C DC/DC/DC PLC with 14 digital inputs, 10 digital transistor outputs and 2 analog inputs. 24 V DC supply, 150 KB program/data memory and PROFINET communication.

RS232 PLC HMI Communication Cable – DB9 Serial Programming Cable for Industrial Automation

Industrial Communication

RS232 PLC HMI Communication Cable – DB9 Serial Programming Cable for Industrial Automation

RS232 serial communication cable for compatible PLCs and HMIs, suitable for programming, configuration, commissioning, diagnostics and industrial automation communication.

Delta VFD EL SERIES 0.025 TO 5 HP | 0.2KW TO 3.7KW

VFD & Drives

Delta VFD EL SERIES 0.025 TO 5 HP | 0.2KW TO 3.7KW

Delta VFD002EL21A 0.2kW (0.25HP) VFD with 200–240V single-phase input, 3-phase output, 1.6A rated output current, V/F control, RS-485 Modbus, built-in braking transistor and 0.1–600Hz frequency range.

Delta DOP-107CV 7 Inch Touchscreen HMI – 800×480 TFT, RS-232/RS-485/RS-422, USB

HMI

Delta DOP-107CV 7 Inch Touchscreen HMI – 800×480 TFT, RS-232/RS-485/RS-422, USB

Delta DOP-107CV 7-inch industrial touchscreen HMI with 800×480 resolution, 65,536-color TFT display, 256 MB RAM/ROM, RS-232/RS-485/RS-422 communication, USB Host/Client, and 24 VDC power supply.

Delta DVP28SV11T2 PLC – DVP-SV2 Series, 16 Digital Inputs, 12 Transistor Outputs, 24V DC

PLC

Delta DVP28SV11T2 PLC – DVP-SV2 Series, 16 Digital Inputs, 12 Transistor Outputs, 24V DC

Delta DVP28SV11T2 DVP-SV2 Series high-performance slim PLC with 16 digital inputs and 12 NPN transistor outputs. Featuring high-speed processing, high-speed counters and pulse outputs, it is suitable for machine automation, motion control, packaging, printing, conveyor and industrial control applications

Delta DVP12SA2 PLC – DVP-SA2 Advanced Slim PLC, 8DI/4DO, 24VDC, RS-232/RS-485

PLC

Delta DVP12SA2 PLC – DVP-SA2 Advanced Slim PLC, 8DI/4DO, 24VDC, RS-232/RS-485

Delta DVP12SA2 DVP-SA2 Advanced Slim PLC with 8 digital inputs, 4 digital outputs, 24VDC supply, 16K steps and RS-232/RS-485 Modbus communication.

Delta DVP60ES200R PLC – DVP-ES2, 36DI/24 Relay Output, 16K Steps

PLC

Delta DVP60ES200R PLC – DVP-ES2, 36DI/24 Relay Output, 16K Steps

Delta DVP60ES200R DVP-ES2 PLC with 36 digital inputs, 24 relay outputs, 100–240VAC power supply and 16K-step program capacity for industrial automation.

Delta DTC1000 Temperature Controller – 24VDC, PID/ON-OFF Control, RS-485 Modbus

PLC

Delta DTC1000 Temperature Controller – 24VDC, PID/ON-OFF Control, RS-485 Modbus

Delta DTC1000 modular temperature controller with 24VDC supply, PID/ON-OFF control, multiple sensor inputs and RS-485 Modbus communication.

Related engineering services

View automation services →

Frequently asked questions

What information is useful for a hvac automation enquiry?

Describe the machine or process, current controls, operating sequence, required modes, available drawings and the changes you want to make. Include known controller and drive models where possible.

Can existing equipment be considered?

Yes. Include the installed controller, HMI, drives, sensors and any drawings or fault details so the existing arrangement can be reviewed before defining scope.

Discuss your automation requirements

Share the equipment details, current controls and process sequence for a scope review.

Request a Quote